Heating and cooling needs on the PreDesign seasons page
Each PreDesign study shows likely heating and cooling needs, as shown below.

This article explains how to use this information and where it comes from.
How to use this information
This information helps you understand how much heating and cooling your building type is likely to need in this climate, by season. You can use it to:
- Compare how useful architectural solutions are for reducing heating or cooling energy.
- Assess the benefits of more efficient heating and cooling systems.
For each season, PreDesign provides 2 pieces of information:
- Frequency of heating and cooling. The number of days in the season when a standard design would typically need heating or cooling switched on.
- Energy Demand. A relative assessment of how much energy you are likely to need for heating, cooling or both in each season.
Use these indicators to guide your design decisions:
- Each level of improvement in insulation or airtightness can remove a flame from each season. If every season has flames, small improvements in insulation may offer much better value than large improvements.
- You can assume that each level of improvement in shading or glazing control, or reduction in glazing ratio, removes a snowflake from each season. Small improvements can have a large impact when several seasons have snowflakes.
- The frequency of heating or cooling shows how concentrated the demand is. If the frequency is low, discuss whether your client needs permanent systems or could use temporary options.
How can architectural design reduce heating demand?
You can reduce heating demand by improving facade insulation and reducing air infiltration. These improvements generally matter more when the floor plate is small relative to the building envelope and ventilation requirements are low. For any building, many flames suggest you should consider better insulation.
Buildings with large floor plates, high ventilation requirements or both are also likely to need heating for ventilation air. Many flames indicate that heat recovery ventilation systems will be more useful.
Use the glazing ratio feature to assess the value of changing insulation types. The % shown can indicate the relative benefits of each design option.
How can architectural design reduce cooling demand?
You can meet cooling demand with mechanical systems, architectural solutions or both. Shading and better-performing glazing limit solar gain and help reduce the number of snowflakes.
For buildings with narrower floor plates, natural ventilation may also reduce the number of snowflakes. It may be an acceptable alternative to air conditioning, especially if no season has 4-5 snowflakes or your client accepts a wider range of indoor temperatures.
Use the glazing ratio and shading features to identify which facades would benefit from shading and compare shading approaches.