Compare energy simulation results and model geometry in Enscape Impact and IES VE.

On this page
  1. Enscape Impact and IES VE
  2. Glazing changes comparison
  3. Impact 4.1 and 4.2 comparisons
  4. Impact 4.5 and 4.6 comparisons

Compare energy simulation results and model geometry in Enscape Impact and IES VE.

Enscape Impact and IES VE

Baseline and variation geometry in Enscape Impact and IES VE, with glazing reduced by 10% and 25%.

Baseline and variations

Glazing changes comparison

Reducing glazing by 10% and 25% gives similar improvements in both applications.

Enscape Impact model

IES VE model

Variance

Enscape Impact model

IES VE model

Variance

Total energy (MWh)

% difference

Total energy (MWh)

% difference

Baseline simulation results

520

-

592

-

12%

Variation 1, glazing reduced by 10%

487

6.3%

542

8.5%

2.2%

Variation 1, glazing reduced by 25%

440

15.4%

493

16.7%

1.3%

Further testing is under way across more model types, locations and design changes. The results will appear in a white paper published with the release.

Overall, the Enscape Impact and IES VE results have a 12% variance.

Overall results

Enscape Impact model

IES VE model

Variance

Enscape Impact model

IES VE model

Variance

Baseline simulation results

Total energy (MWh)

Total energy (MWh)

Total energy (MWh)

520

592

12%

Heating (MWh)

134

260

48%

Cooling (MWh)

33

28

18%

Hot water (MWh)

32

32

0%

Lighting (MWh)

167

155

8%

Equipment (MWh)

154

116

33%

EUI (kWh/m2)

105

119

12%

The baseline results for Enscape Impact and IES VE are within an acceptable tolerance. Known reasons for the differences include how Enscape Impact models geometry and the default datasets each application uses. Both factors are expected to improve.

Geometry comparison

Enscape Impact model

IES VE model

Variance

Enscape Impact model

IES VE model

Variance

Spaces (m2)

33

40

21.2%

Volume (m3)

7,247

6,699

7.6%

Ground floor area (m2)

768

739

3.7%

Roof area (m2)

1,315

766

41.7%

Internal floor area (m2)

2,167

2,167

0.0%

Ceiling area (m2)

2,236

2,167

3.1%

Total floor area (m2)

2,935

2,906

1.0%

External wall area (m2)

1,137

1,278

12.4%

External door area (m2)

-

3.40

-

External glazing area (m2)

95

123

30.5%

Enscape Impact uses IES Apache technology. For more information, watch the Enscape Impact Video Tutorial.

Impact 4.1 and 4.2 comparisons

Table comparing IES VE energy use and EUI with Impact 4.1 and 4.2 across building types and model changes.

Click the image to view it in full screen.

Impact 4.5 and 4.6 comparisons

Download the compressed PDFs for detailed comparison tables for versions 4.5 and 4.6.

Download comparison tables

Table comparing Impact 4.5 and 4.6 energy use and EUI with IES VE across building types and model changes.

Click the image to enlarge it.

Procadsys customer support

Still need help?

Licences, renewals and billing

Our New Zealand team looks after your Enscape licences, renewals and invoices.

Monday to Friday, 9:00 am to 4:30 pm NZ time, excluding New Zealand public holidays.

Technical problems

Installation errors, crashes and other technical problems with Enscape are handled by Chaos support.